EasyManua.ls Logo

Ariston FLECK NILO - Legionella Bacteria Function; Technical Characteristics

Ariston FLECK NILO
44 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15 / EN
LEGIONELLA BACTERIA FUNCTION
Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries’
disease is a pneumonia infection caused by inhaling of Legionella species. Long periods of water stagna
-
tion should be avoided; it means the water heater should be used or flushed at least weekly.
The European standard CEN/TR 16355 gives recommendations for good practice concerning the preven
-
tion of Legionella growth in drinking water installations but existing national regulations remain in force.
This electronic storage water heater is sold with a thermal disinfection cycle function enabled by default.
Every time the product is switched on and every 30 days, the thermal disinfection cycle run to heat the
water heater up to 60°C.
Warning:
when this software has been carrying out the thermal disinfection treatment, water temperature
can cause burns. Feel water before bathing or showering.
TECHNICAL CHARACTERISTICS
For the technical specifications, refer to the nameplate (the nameplate is located next to the water in-
take/outlet pipes).
TABLE 1 - PRODUCT INFORMATION
FLECK NILO range 15 25 50 75
100 150 200
Weight kg 11,7 16,1 21,7 29
35 47,8 56,5
Installation Vertical Vertical Vertical Vertical Vertical Vertical Vertical
Model
Refer to the nameplate
SMART x x x x x x x
Q
elec
kWh 3,129 3,134 7,263 6,954 7,221 13,216 13,986
Q
elec , week, smart
kWh 12,810 14,627 26,229 26,370 27,386 54,797 53,322
Q
elec , week,
kWh 15,778 17,647 33,454 33,519 36,304 60,911 65,680
Load profile XXS S M M M L L
L
wa
15 dB
η
wa
34,4% 33,8% 40,0% 40,0% 40,0% 39,4% 39,1%
V40 l -- -- 70 129 170 243 336
Capacity l 15 24 50 75 100 150 200
FLECK BON range -- 25 50 75
100
-- --
Weight kg -- 15 20,3 27,5
33,5
-- --
Installation -- Verticale Verticale Verticale Verticale -- --
Model
Refer to the nameplate
SMART -- x x x x -- --
Q
elec
kWh -- 3,134 7,454 7,454 7,451 -- --
Q
elec , week, smart
kWh -- 14,627 27,273 25,570 30,592 -- --
Q
elec , week,
kWh -- 17,647 33,417 34,768 35,634 -- --
Load profile -- S M M M -- --
L
wa
15 dB
η
wa
-- 33,8% 39,7% 40,0% 37,3% -- --
V40 l -- -- 72 129 170 -- --
Capacity l -- 24 50 75 100 -- --
The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure
A to this manual) are defined in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated in regulation
812/2013, are not intended to be used in such assemblies.
The device is equipped with a smart function that allows you to adapt the consumption to the user profiles. If
operated correctly, the device has a daily consumption of "Qelec* (Q
elec, week, smart
/Q
elec, week
) less than that of an
equivalent product with no smart function".
The data on the energy label refer to the product installed vertically (installation recommended by the manu
-
facturer).

Related product manuals