area tecnica technical area
5 PARAMETRI ZONA 2
5. 0 IMPOSTAZIONE TEMPERATURE ZONA 2
5. 0. 2 Impostazione Temperatura
Fissa Riscaldamento
da 35 a 82 (°C) 70
Da impostare per termoregolazione a temperatura  ssa
(vedi 521)
5. 2 IMPOSTAZIONE ZONA 2
5. 2. 1 Selezione Tipologia
Termoregolazione in base
alle periferiche connesse
Per attivare la
Termoregolazione premere
il tasto AUTO. Sul display
compare il simbolo
0 = Temperatura
ssa di
mandata
1 = Dispositivi
ON/OFF
2 = Solo sonda
ambiente
3 = Solo Sonda
Esterna
4 = Sonda ambiente
+ sonda esterna
1
5. 2. 2 Selezione curva
Termoregolazione
da 1.0 a 3.5
(imp. alta temp.)
1.5
vedi gra co parametro 422
Nel caso di utilizzo della sonda esterna, la caldaia calcola
la temperatura di mandata più idonea tenendo conto
della temperatura all’esterno e del tipo di impianto.
Il tipo di curva va scelta in funzione della temperatura
di progetto dell’impianto e dell’entità delle dispersioni
presenti nella struttura.
Per impianti ad alta temperatura è possibile scegliere tra
una delle curve a lato rappresentate.
5. 2. 3 Spostamento parallelo della
curva di termoregolazione
da - 14 a + 14 (°C) 0
Per adattare la curva termica alle esigenze dell’impianto
è possibile spostare parallelamente la curva così da
modi care la temperatura di mandata calcolata e quindi
la temperatura ambiente.
Accedendo al parametro e ruotando l’encoder si può
spostare parallelamente la curva. Il valore di spostamento
è leggibile sul display. Ogni step equivale ad un aumento/
diminuzione 1°C della temperatura di mandata rispetto al
set-piont.
5. 2. 4 Impostazione in uenza
del sensore ambiente per il
calcolo della temperatura di
set-point
- Termoregolazione attivata-
da 0 a 20 20
Se impostato a 0 la temperatura rilevata dal sensore
ambiente non in uisce sul calcolo del setpoint. Se a 20, la
temperatura ambiente rilevata ha la massima in uenza
sul calcolo del setpoint. Attivo con dispositivi modulanti
collegati.
5. 2. 5 Impostazione temperatura
massima riscaldamento
Zona 2
da 35 a 82 °C 82
5. 2. 6 Impostazione temperatura
minima riscaldamento
Zona 2
da 35 a 82 °C 40
5. 3 DIAGNOSTICA ZONA 2
5. 3. 4 Stato richiesta di calore
Zona 2
0 = OFF
1 = ON
5 ZONE 2 PARAMETER
5. 0 ZONE 2 TEMPERATURE SETTING
5. 0. 2 Fix temperature central
heating
from 35 to 82 (°C) 70
To set only with Fixed Flow Temperaure of
Thermoregulation (see 521)
5. 2 ZONE 2 SETTING
5. 2. 1 Select Type of
Thermoregulation
To enabled thermoregulation
press Auto button.
On the dispaly will appear the
symbol
0 = Fixed Flow
Temperature
1 = Basic
Thermoreg.
2 = Room sensor
3 = Outdoor Temp.
only
4 = Room sensor +
outdoor Temp.
1
5. 2. 2 Zone 1 Slope from 1.0 to 3.5
(high temperature)
1.5
See parameter 422
Only enabled when an outdoor sensor is installed
When an outdoor sensor is used, the boiler calculates the
most suitable delivery temperature, taking into account
the outside temperature and type of system. The type
of curve should be selected in correspondence with the
projected temperature of the system and the nature of the
dispersions present in the structure. For high-temperature
systems, one of the curves depicted below may be chosen.
5. 2. 3 Parallel curve shift Zone 2
O set
from - 14 to + 14
(°C)
0
To adapt the heating curve to the system requirements,
shift the curve in parallel so that the calculated  ow
temperature is modi ed, in addition to the room
temperature.
By accessing the parameter and turning the encoder,
it is possible to shift the curve in a parallel direction.
The shifting value can be read on the display. Each
step corresponds to a 1°C increase/decrease In the  ow
temperature with respect to the set-point value.
5. 2. 4 Room sensor In uence
to calculate the set-
point temperature -
Thermoregulation enabled-
from 0 to 20 20
If setted = 0 the room temperature doesn’t in uence the
calculation of the set-point.
If setted = 20, the room temperature has the maximun
in uence to calculate the set-point
- only active when the BUS device is connected
5. 2. 5 Maximum Central Heating
Temperature Zone 2
from 35 to 82 °C 82
5. 2. 6 Minimum Central Heating
Temperature Zone 2
from 35 to 82 °C 40
5. 3 DIAGNOSTICS
5. 3. 4 Heat Request Zone 2 0 = OFF
1 = ON
menu
sotto-menu
parametro
descrizione range
impostazioni di
fabbrica
note
menu
sub-menu
parameter
description value
default
setings
notes