6.3.3 Removing the electrodes
Before carrying out this procedure, unscrew and slide the
burner forward (see previous section).
1. Remove rubber gasket “G” (FIG. 6.12);
2. To remove the detection electrode disconnect the cable at
its connection point close to the P.C.B. (FIG. 6.13);
3. Remove screw “H” (FIG. 6.14);
4. Gently slide the electrode downward (FIG. 6.15).
FIG. 6.12
G
FIG. 6.13
6.3.2 Removing the burner and jets
1. Remove the screws “F” from the burner (FIG. 6.10);
2. Remove the burner (FIG. 6.11);
3. Disconnect the electrodes (see SECTION 6.3.3);
4. Remo
v
e the jets using a No
. 7 socket spanner;
5. Replace in reverse order.
6.3.1 Removing the combustion cover
1. Remo
ve the screws “E” (F
IG.
6.9);
2. Lift off the comb
ustion cover.
6.3 ACCESS TO THE COMBUSTION CHAMBER
E
E
FIG. 6.9
FIG. 6.10
Fig.
6.11
E
E
F
F