FIG. 6.38
Z
FIG. 6.39
FIG. 6.40
FIG. 6.37
6.5.2 Removing the pump pressure switch
1.Remove the pump pressure switch electrical connections
“Z”
(F
IG 6.38
);
2.Unscrew the pump pressure switch by
using
a spanner on
the nut (FIG 6.39);
3.Remove the pump pressure switch (FIG 6.40).