10) ERROR EF
Cause: Occurs when flow sensor stops sending pulses for a certain period of time
Number of pulses is less than 10/sec with water inlet solenoid valve powered
Action: Check solenoid valve powered time (5.5 sec with EEPROM.)
Error terminates when flow sensor is replaced.
11) ERROR E9
Cause: Temperature detected by ice sensor increases 5 m after water inlet
Action: Normal procedure
Error terminates when sensor detects correct temperature
(IS detects insufficient water in ICE tray)
12) ERROR ES (DISPENSER MICROSWITCH)
Cause: When microswitch is active for more than 1 minute
Action: Stops ice distribution and crushing function.
Display: Ice dispensing LED extinguished.
Error terminates when switch returns to normal status
13) Ice drop motor operation fault
Cause: Motor malfunction
Action: Press TEST SWITCH button
Renew motor
14) ERROR Eu
Cause: Switch responsible for detecting ice tray full condition generates error
Action: When ice is dropped microswitch fails to return to ON position
Error terminates when switch returns to normal status
15) ERROR EA (tray rotation motor error)
Cause: Ice drop is detected 3 times by the sensor with the level sensor switch signalling an error
condition
Action: Stop operation of ice maker
Error terminates when level sensor switch returns to normal status
* Switch off power supply and then switch on again or press test switch
16) ERROR Et
Cause: Occurs when level sensor signals an error (no pulses detected for a certain period of time)
Action: By time (supply mode no longer valid)
(tray horizontal position)
Error terminates when sensor normal status is restored
* When all ERROR CODES are normal, fridge settings are all reset.