EasyManua.ls Logo

Ariston MSZ 70 NF COOLING 2004 - Forced Defrost; Initial Defrosting; Audible Signal or Alarm

Ariston MSZ 70 NF COOLING 2004
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Merloni Elettrodomestici
Instruction Manual Language Edition Page
Side-By-Side Refrigerator – Ariston MSZ 70 NF EN 2004.11.11 28 - 88
1.5.9. F
ORCED
D
EFROST
Input Controlled Device
1. FREEZER SET button
2. FRIDGE SET button
Defrost mode
1. Initial procedure: set test mode
Press FRIDGE SET button 5 times while simultaneously holding down FREEZER SET button
2. How to proceed
1) Deselect Pre-cooling mode (other modes are identical to normal defrosting)
2) Heating element is ON irrespective of temperature measured by defrost sensor during first 30 sec.
(Check defrost current)
(use in A/S for heating element power absorption test)
1.5.10. I
NITIAL DEFROSTING
Input Controlled Device
Defrost sensor
Initial connection of appliance to power supply
Defrost mode
If the defrost sensor temperature is </= 3.5°C, defrost mode starts from Pre-cooling mode at the first power-up
Note: The comp is delayed by 6 min. at initial defrosting
1.5.11. A
UDIBLE
S
IGNAL
O
R
A
LARM
Input Controlled Device
Freezer control panel buttons
Door switch
Initial power-up
AUDIBLE SIGNAL
Description Beeps / Tones
1. The appliance emits an audible signal on pressing
any of the buttons on the freezer control panel
1 beep
2. The appliance emits 4 beeps 3 sec. after power-up 1 time 4 beeps
3. Appliance audible signal 3 times in event of forced
defrost A/S short circuit, demo mode
1 time 3 beeps
4. If door is open audible signal sounds every minute
for 5 minutes.
(Door open alarm)
3 beeps per min. for 5 min.