EasyManua.ls Logo

Ariston MSZ 70 NF COOLING 2004 - Adjustment of Fridge Probe off Set-Point

Ariston MSZ 70 NF COOLING 2004
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Merloni Elettrodomestici
Instruction Manual Language Edition Page
Side-By-Side Refrigerator – Ariston MSZ 70 NF EN 2004.11.11 32 - 88
1.5.19. A
DJUSTMENT OF
F
RIDGE
P
ROBE
O
FF
S
ET
-P
OINT
Input Controlled Device
Main control panel Fridge probe intermediate ON/OFF point
resistor
Fridge probe ON/OFF point resistor (1.5°C reduction)
If cooling or fridge power are low or insufficient, proceed as follows
A = Fridge Probe
Cutting the resistor leads results in lowering of the temperature in REF:
1st cut J 18 = 1.5°C lower (colder)
2nd cut
R26: Standard resistor of fridge probe in normal mode (31.4K)
R37: In event of insufficient cooling reduce J18 to lower standard resistance by
1.5°C (2K)
R38: In event of insufficient cooling reduce J19 to lower standard resistance by
1.5°C (2K)
R36 = Intermediate ON/OFF point
R36 + R37 = Intermediate ON/OFF point - 1.5°C
R36 + R37 + R38 = Intermediate ON/OFF point - 3.0°C
J 19 = 3°C lower (colder)

Table of Contents