3) Water pipe heating element check
* The heating element is always ON if the room probe is in error of if TA (room temperature) is > 15°C.
* The heating element is always ON for 60 min (max. time limit) if the Flow-sensor is subject to an error
(otherwise it is ON with the compressor)
4) Water supply ready mode
Condition: detection of ice maker full.
Action: system proceeds with ice production mode (Ice drop and water supply mode are suspended).
Process terminates in normal conditions.
5) Ice crushing function
The function stops if the freezer door is open
The function is active with the freezer door closed
1-2. Ice Production Mode
Start = Avvio
ICE Sep. = Ice separation mode.
A. 130 minutes elapsed?
B. Ice probe temperature < -12.5°C ?
C. Ice probe temperature < -9.5°C ?
D. 15 minutes elapsed?
1) Ice production suspended (if ice sensor temperature is < -12.5°C) after 130 min.
2) Ice production suspended even if ice probe temperature is < -9.5 °C for 15 min even though ice probe
temperature > -12.5°C after 130 minutes.
(even if 130' not elapsed and not at -12.5°C)
3) In the event of an ice probe error ice production stops for approx. 4h (2x130', normal ice production time)