87 / GB
MENU
SUB-MENU
PARAMETER
DESCRIPTION
RANGE DEFAULT
17 5 3 Max HP charging time 30 ÷ 240 min. 120 min.
17 5 4 Antilegionella Function ON - OFF ON
17 5 5 Antilegionella start time [hh:mm] [00:00-24:00] 01:00
17 5 6 Thermal Cleance Cycle frequency 24h ÷ 481 (= 30 days) 481 (= 30 days)
17 6 Manual Mode - 1
17 6 0 Manual mode activation OFF - ON OFF
17 6 1 HP circulator control
OFF
Low Speed
High Speed
OFF
17 6 2 Diverter valve control
DHW
CH
DHW
17 6 3 Diverter valve COOLING
CH
COOLING
CH
17 6 4 Auxiliary circulator OFF - ON OFF
17 6 5 Output AUX 1/2 contact OFF - ON OFF
17 6 6 Test resistance 1 OFF - ON OFF
17 6 7 Test resistance 2 OFF - ON OFF
17 6 8 Test resistance 3 OFF - ON OFF
17 6 9 Anode output OFF - ON OFF
17 7 Manual Mode - 2
17 7 0 Manual mode activation OFF - ON OFF
17 7 1 Force Hp Heat OFF - ON OFF
17 7 2 Force Hp Cool OFF - ON OFF
17 7 3 Rating heating mode OFF - ON OFF
17 7 4 Rating cooling mode OFF - ON OFF
17 7 5 Compressor frequency setting 18 ÷ 120 Hz 120 Hz
17 7 6 Fan 1 rpm setting 0 ÷ 1000 rpm 0 rpm
17 7 7 Fan 2 rpm setting 0 ÷ 1000 rpm 0 rpm
17 7 8 TDM aux output (NOT used) OFF - ON OFF
17 7 9 Ext Unit Electric Heater Activation OFF - ON OFF
17 8 Test & Utilities
17 8 0 Air-purge function OFF - ON OFF
17 8 1 Floor drying cycle
OFF
Functional Heating
Curing Heating
Functional Heating + Curing Heating
Curing Heating + Functional Heating
Manual
OFF
17 8 2 Floor drying total Remaining Days only read
17 8 3 Floor drying functional Remaining Days only read
17 8 4 Floor drying curing Remaining Days only read
17 8 5 Refrigerant Recover OFF - ON OFF
17 8 6 Resistance Power Rating Configuration
2+2(+2) kW
2+4 kW
2+2(+2) kW
17 8 7 Defrost OFF - ON OFF
17 8 8 TDM Flow Sensor Type
Self-Recognition
DN 15
DN 20
Self-Recognition
17 9 Energy Manager Statistics only read
17 9 0 HP Running hours (h/10) only read
17 9 1 HP On cycles (n/10) only read
17 9 2 Resistor Stage 1 running hours (h/10) only read
17 9 3 Resistor Stage 2 running hours (h/10) only read
17 9 4 Resistor Stage 3 running hours (h/10) only read
17 9 5 Resistor Stage 1 On cycles (n/10) only read
17 9 6 HP Defrost hours (h/10) only read
17 9 7 Cooling running hours (h/10) only read