/ 69
MENU
SUB-MENU
PARAMETER
DESCRIPTION RANGE FACTORY SETTINGS
5 2 2 Slope 0,2 - 1 (LT); 1 - 3,5 (HT)
0,6 (LT) - 1,5 (HT)
523Offset -7°C + 7°C (LT); -14°C ; 14°C (HT)
0
524Room Infl uence Proportional O°C - 20°C
2°C (LT) - 10°C (HT)
525Max T 20°C - 45°C (LT); 35°C - 82°C (HT)
45°C (LT) - 82°C (HT)
5 2 6 Min T 20°C - 45°C (LT); 35°C - 82°C (HT)
20°C (LT) - 35°C (HT)
5 3 Z2 Diagnostics
530Room T
read only
531Room T setpoint
read only
532Flow temperature
read only
533Return temperature
read only
534Heat Request Z2
read only
5 3 5 Pump status
read only
5 4 Z2 Zone Module Settings
540Zone Pump Modulation
Fixed
Modulating on DeltaT
Modulating on Pressure
Modulating on DeltaT
541Target deltaT for pump modulation 4°C - 25°C
7°C (LT) - 20°C (HT)
5 4 2 Pump fi xed speed 20% - 100%
100%
9 HYBRID Param
9 0 User Parameters
9 0 0 Hybrid Mode
Auto
Only Boiler
Only HP
Auto
9 0 1 Energy Manager Logic
Max Saving
Max Ecology
Max Ecology
9 0 2 ECO / COMFORT
ECO PLUS
ECO
AVERAGE
COMFORT
COMFORT PLUS
Average
9 0 3 Thermoregulation
Absent
Present
Present
9 0 4 Quiet Mode Activation ON - OFF
OFF
9 0 5 Quiet Mode start time [hh:mm] 00:00 - 24:00
22:00
9 0 6 Quiet Mode end time [hh:mm] 00:00 - 24:00
06:00
9 0 7 PV integration
not active
active
not active
9 0 8 PV Delta T DHW Setpoint Temp. 0°C - 20°C
0°C
9 1 Energy manager parameter 1
9 1 0 Hydraulic scheme
none
WHB Combi
WHB + tank
None
9 1 1 FlowT HP Offset 2°C - 10°C 2°C
9 1 2 Text for Boiler disabling 25°C - 40°C 35°C
9 1 3 Text for HP disabling -2O°C - 0°C 0°C
9 1 4 External temperature correction -3°C - +3°C 0°C
9 1 5 Pro-Tech anode active OFF - ON OFF