User Menu
49 / EN
2.11.4 Buffer tank
Buffer
Buffer activation
OFF
Buffer comfort setpoint heating
40 °C
Reduced Setpoint heating
20 °C
Buffer comfort setpoint cooling
18 °C
Reduced Setpoint cooling
23 °C
Buffer setpoint mode Fixed
Fig. 74
Buffer
Buffer setpoint mode
Fixed
Control mode Always active
Fig. 75
This function is available only if the system is fitted with a tech-
nical water storage tank (buffer) for heating and/or cooling.
"Buffer activation": allows to enable/disable the buff-
er charge.
"Buffer comfort setpoint heating": sets the desired
buffer charge temperature in heating mode for the
comfort slot.
"Reduced Setpoint heating": sets the desired buffer
charge temperature in heating mode for the reduced
slot.
"Buffer comfort setpoint cooling": sets the desired
buffer charge temperature in cooling mode for the
comfort slot.
"Reduced Setpoint cooling": sets the desired buffer
charge temperature in cooling mode for the reduced
slot.
"Buffer setpoint mode": sets the buffer charge mode.
"Fixed": the buffer charge temperature is defined
in the parameters shown above.
"Variable": the buffer charge temperature is calcu-
lated according to the automatic temperature con-
trol function (if active).
"Control mode": setting of the buffer charge operat-
ing mode (“Disabled”/”Time Based”/”Always active”)
2.11.5 Heat Pump
This menu is available only if a heat pump with the heating/
cooling functions is installed. For further information, see the
product manual.
Heat Pump
Quiet mode
>
CH aux heat source activation
logic
Heat integr. and
backup
DHW aux heat source
activation logic
Heat integr. and
backup
DHW operation mode Standard
Fig. 76
"Quiet mode": the following settings allow for reduc-
ing the noise level of the heat pump by limiting the
compressor frequency.
a
Activating this function may reduce the ma-
chine’s performance.
"Quiet mode activation HHP": enables/disables
the silent mode.
"Quiet mode start time HHP [hh:mm]": sets the
time for the machine to start working in silent mode.
"Quiet mode end time HHP [hh:mm]": sets the
time for the machine to stop working in silent mode.
"CH aux heat source activation logic": the param-
eter allows to choose when to activate the secondary
heat source (heating elements, if enabled or present, or
an auxiliary heat source) of the heat pump in heating
mode.
In case of a heat pump malfunction and for heat
production integration (“Heat integr. and backup”):
the secondary heat source is activated both to inte-
grate heating at the heat pump and in case of a heat
pump malfunction.
Only in case of a heat pump malfunction (“HP fail-
ure backup”): the secondary heat source is activated
only in case of a heat pump malfunction.
"DHW aux heat source activation logic": the param-
eter allows to choose when to activate the secondary
heat source (heating elements, if enabled or present,
or an auxiliary heat source) of the heat pump in DHW
mode.