CONTINUED OPERATING
6. Plug in the power cord to a power
outlet and the current ambient air
temperature will be displayed on
the digital thermometer. If this
temperature is above 35C, freezing
pipes may not be possible. Should
the Icecap-Pro pipe freezer have
been stored in a hot location such
as a car on a hot summers day,
before using press the power button
and the cooling fans will start, the
temperature will lower to the
ambient room temperature.
7. Press the freeze button
and the
jaw temperature will begin to drop.
7
6
8. Factors that affect the freezing
times are:
a The ambient air temperature.
b The size of the pipe. Larger pipes
take longer to freeze than smaller
pipes.
c The quality of thermal contact
between the freezing components
and the pipe.
d The temperature of water within
the pipe.
e The level of solar radiation. If
possible, keep out of direct sunlight.
f Contaminated water. Corrosion
inhibitors or anti-freeze within
central heating systems may slow
or possibly prevent freezing in
high concentrations.
IMPORTANT
The Icecap-Pro contains an
accurate and fast responding
digital thermometer. During
the freezing process it may be
noticed that the temperature
rises a few degrees quite
quickly before stabilising.
This is not a fault with the
machine but is caused by ice
breaking away from an ice
plug as it is being formed and
being replaced by warmer
water from below.