7 - Programmed Setpoint
7.3 CREATION AND
MODIFICATION OF A PROG.
band dO. I
275.8
Menu
274.8
prog
stat
fail
Unit
n.seg
Cyc.
ti. O
sp. 0
dO. O
ti. I
sp. 1
sp. f
dO. f
Program status
res = reset
Hold= hold
run = start
Restart
after a power off
Cont= continue
res = reset
raMp= continue with
the slope
Time units
p.sec = seconds
p.Min = minutes
p.hr = hours
of segments
1…14 max
of program cycles
Off / 19999
Allowed deviation
Off / 0…span/20
Segment 0
time
0.1…999.9
Unit
Segment 0
Setpoint
whole range
Segment 0
Digital output [1]
Clo = closed
Opn = open
Off = inhibited
Segment 1
time
0.1…999.9
Unit
Segment 1
Setpoint
Intera scala
Segment 1
Digital output [1]
End
segment Setpoint
whole range
End segment
digital output[1]
Clo = closed
Opn = open
Off = inhibited
Operator
mode
Program menu
(if present)
Back to the
1st parameter
[1] One digital output is provided
which can be controlled by the
program. This output is OP3. If this
functionality is not required, it can
be inhibited by setting Off the
parameter àd.O.--
PARAMETER MENU
Continue for
all the 14 normal
segments
M5 UK•ed4 10-12-2004 16:20 Pagina 37