WM 220
The various water levels are indicated by:
P1 Return to normal level Indicated by 1
P2 Normal wash level Indicated by 2
P3 Normal rinse level Indicated by 3
P4 High rinse & wash level Indicated by 4
P5 Overfilled Indicated by 5
Stop the test program by pressing the Stop button.
Faults are indicated by:
F1 Water supply (if the correct level has not been reached in five
minutes).
F2 Overfilling (if the overfill level has lasted for more than 60
seconds).
F3 Fault in pumping out (if the water level above P1 after the outlet
pump has run for 3 minutes).
F4 Thermistor fault.
F5 Heating pause fault )if the selected temperature has not been
reached within 90 minutes).
F6 Motor fault.
F7 Door lock release fault.
Indicates that the machine has not spun i.e. to reduce serious out-of-
balance.
Temperature block
In the wool program, the temperature stop step has been maximized to 24
minutes. This means that if the temperature by mistake is set on, say 90°C, the
temperature still will not be higher than good 40°C, (can vary a little depending
on the temperature of incoming water, the size of the load etc.).
In Whites wash/Cotton programs and in the synthetic programs the time for the
temperature stop is maximized to 80 min. This prevents among other things the
water to cook by broken thermostat (if the capillary tube is broken) or that the
machine goes on "for ever" by broken heater.