ASSA ABLOY motor locks installation guide
16
DIP Operation Relay Standard operation Operation for SSF3522
1
Pair Hi-O units Door closed: Relay is activated when door is closed.
2 Activates/deactivates door position
sensor in lock case.
If DIP 2 is ON during pairing: Door
position sensor in lock case is deactivated.
Deadlock: Mirrors latch position: Relay is deactivated after 15 seconds
3
DIP = OFF, normal mode: Inside handle: Relay is activated when the inside handle is down.
DIP = ON: Outputs operate according to
requirements of SSF3522.
Error: Activated if the lock fails to lock or if there is a communication fault
on the Hi-O bus.
Red LED flashes at one-second intervals (1 Hz) if there is a
communication on fault.
All other relays are deactivated if there is a communication fault and
return to their original state when communication is restored.
SSF3522: Relay is activated for the
same type of fault but is deactivated
after 120 seconds.
4 DIP = OFF: Door forced output remains
active after door has been forced.
Output is reset via Unlock input.
Door forced:
See description for DIP 4.
Door forced:
In SSF3522 mode the output
switches function and indicates when
the door is unlocked; the output is
deactivated after 120 seconds.
DIP = ON: Forced door output is
deactivated when door is closed.
Door forced NC
Door forced C
Door forced NO
Error NC
Error forced C
Error forced NO
Handle NC
Handle C
Handle NO
Deadlocked NC
Deadlocked C
Deadlocked NO
Door closed NC
Door closed C
Door closed NO
Sabotage NO
Sabotage C
0 V (Power in)
+12-28 V
0 V out to lock Yellow
+12-28 V out to
lock Green
CAN-L Brown
CAN-H White
Input
0 V Unlock fire
+12-28 V
Door monitor
Closed = Close door
Door monitor
operates in series with
lock’s door position
sensor
Unlock
Closed = Unlocked
Input
0 V Unlock fire
+12-28 V