DIP8=ON, DIP7=OFF: Function of relays and inputs
(KP2) DAC400RC64 relay board (Applies to Standard & EMLA)
RE1 RE2 RE3 RE4 RE5 RE6 IN1 IN3
Bolt out Bolt in Unlocked Door position Buzzer Tamp D/N Alarm blocking
KP1 DAC530 board
DIP 3 DIP 4 Function Out
Relay
(Lock)
Out
Relay
(Alarm)
IN
13 & 14
Door monitor
IN
11 & 12
Button
OFF OFF Standard Electric strikes Alarm Bypass Door position
in
Open
ON OFF EMLA Bolt out.
The relay
takes hold for
15 sec
Bolt in.
The relay
takes hold for
15 sec
Door position
in
Open
OFF ON Invalid mode
OFF ON Invalid mode
With DIP8 = ON, DIP7 = ON:
The unlock time is set with
Sec./DIP 1 2
4
8 ON
12 ON
16 ON ON
Information!
DAC and other Hi-O products have a function inhibiting them for
240 seconds (4 minutes) if the initiation fails more than three times,
when the time expires you have one more chance to try to initiate.
Note that the time only counts when the Hi-O unit has power.
After initiation DAC and other units cannot be moved to another
door unless they are “uninitiated” from each other, see user guide.
For ASSA motor lock see “Factory recovery ASSA motor lock”.
For more information, see manual.