17
R
TECHNICAL DATA ENGLISH
Operating voltage: 12 (-10%) – 24 (+15%) V DC STAB
Current: 12 V DC Max. 1 700 mA
Motor drive 600 mA (50 N seal force)
Idle 50 mA
24 V DC Max. 700 mA
Motor drive 250 mA (50 N seal force)
Idle 25 mA
Micro switch: Max. 100 mA 30 V AC/V DC resist, 3 W
Ambient temperature: -20° - +60° C
Adjustable delay: 1 - 20 sec
Bolt throw: 14 mm / 20 mm (EL590)
14 mm (PE590)
Backset: 50 mm
Forend: 22 mm (morticed)/ 25 mm (surface mounted), chrome plated
Spindle: 8 mm
Selectable functions of the lock case:
Mechanical functions
- opening direction of trigger bolt and latch bolt
- bolt throw (14 mm / 20 mm) (EL590)
Electrical functions
- handle function (mechancial or electrically controlled) (EL590)
- adjustable delay 1 - 20 sec
Monitoring: Bolt deadlocked
Handle down
Cylinder and/or thumbturn monitoring (available as an accessory)
Bolt in (for door automatics)
(Indications are not available during power failure)
Door gap: 2 – 5.5 mm (distance between forend and striker plate)
Connection cable: EA217 (6 m), EA227 (10 m), EA228 (0,5 m) 18 x 0.14 mm2
Strike plate: LP712/LP722/LP732
In fi re doors please use 14mm bolt throw (factory setting 20 mm).
TESTED ACCORDING TO THE STANDARDS
EN STANDARDS
EN 179: 1997/A1: 2001 3 7 6 1 1 3 4 2 A Exit (EL590)
EN 1125: 1997/A1: 2001 3 7 6 1 1 3 3 2 A Panic exit (PE590)
EN 1634-1 Fire
EN 61000-6-1:2001 EMC
EN 61000-6-3:2001 EMC
EN 12209: 2004 Mechanical strength
!