5400LN Series Grade 1
Cylindrical Lever Lockset
Installation Instructions
6
1-855-557-5078 Ext. 2 • www.accentra-assaabloy.com
Copyright © 2002, 2013, 2023, 2024, ASSA ABLOY ACCENTRA™ Access and Egress Hardware Group, Inc. All rights reserved. Reproduction
in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
80-9150-0056-010 04/24
To remove cylinder handle
1. Insert key and rotate clockwise 70°.
2. Depress retainer with tool provided.
3. Slide lever off lock. (Also applies to inside lever of
5417N, 5421LN and 5430LN lock functions.)
To remove cylinder from handle
4. Remove retainer spring pad.
5. Slide cylinder out of handle.
To reassemble reverse procedure. (Be sure spacer is
installed on back of cylinder plug.) Water may be used to
lubricate spring pad to aid installation.
#1802
Cylinder
Retainer Spring Pad
14-5407-9034
Lever Handle
3
1
2
For 7 pin cylinder cut to
11/32" as shown