2. Power Mode
C. Con guration of DIP Switch Setting ("S")
D. LED Signaling
For MELR applications using the optional “S” latch bolt monitor switch, pin 5 of the
8-pin ElectroLynx connector will be either a NO contact or NC contact, depending on
the position of the DIP switches on the motor controller faceplate (Figure 14).
DIP Switch Setting for “S” Latch Bolt Monitoring
NO (Default) Shown
NC Alternative DIP Switch Setting
Figure 14 - Molex with 12-pin Connector Pinned
Signal
Dark / Unlit
Solid Light
Controller microprocessor is
not active
2 Flashes
Followed by Pause
Input voltage is dropping out
of operation range
Con rm connections and incoming power
Steady Flashing
Normal operation
Retractor sensor problem Call 1-800-810-9473 for assistance
Check that Power Mode switch is set
Check wire run and power supply output
Cause Troubleshooting