Select a unique EAC address 1-15 for each
communication hub by use of the DIP switch
according to the table below. (The resulting lock
addresses for each communication hub address
are shown to the right):
DIP 4 – DIP 1 AH30 Hub address Lock addresses
0000 Reserved
0001 0x01 0x01, 0x11, 0x21, 0x31, 0x41, 0x51, 0x61, 0x71
0010 0x02 0x02, 0x12, 0x22, 0x32, 0x42, 0x52, 0x62, 0x72
0011 0x03 0x03, 0x13, 0x23, 0x33, 0x43, 0x53, 0x63, 0x73
0100 0x04 0x04, 0x14, 0x24, 0x34, 0x44, 0x54, 0x64, 0x74
0101 0x05 0x05, 0x15, 0x25, 0x35, 0x45, 0x55, 0x65, 0x75
0110 0x06 0x06, 0x16, 0x26, 0x36, 0x46, 0x56, 0x66, 0x76
0111 0x07 0x07, 0x17, 0x27, 0x37, 0x47, 0x57, 0x67, 0x77
1000 0x08 0x08, 0x18, 0x28, 0x38, 0x48, 0x58, 0x68, 0x78
1001 0x09 0x09, 0x19, 0x29, 0x39, 0x49, 0x59, 0x69, 0x79
1010 0x0A 0x0A, 0x1A, 0x2A, 0x3A, 0x4A, 0x5A, 0x6A, 0x7A
1011 0x0B 0x0B, 0x1B, 0x2B, 0x3B, 0x4B, 0x5B, 0x6B, 0x7B
1100 0x0C 0x0C, 0x1C, 0x2C, 0x3C, 0x4C, 0x5C, 0x6C, 0x7C
1101 0x0D 0x0D, 0x1D, 0x2D, 0x3D, 0x4D, 0x5D, 0x6D, 0x7D
1110 0x0E 0x0E, 0x1E, 0x2E, 0x3E, 0x4E, 0x5E, 0x6E, 0x7E
1111 0x0F 0x0F, 0x1F, 0x2F, 0x3F, 0x4F, 0x5F, 0x6F, 0x7F
The following figure shows an example of a default
installation.
Lock
0x01
Lock
0x11
Lock
0x21
Lock
0x02
Lock
0x03
Lock
0x13
Lock
0x04
Lock
0x14
Lock
0x34
Lock
0x44
Lock
0x24
Lock
0x1F
Lock
0x2F
Lock
0x0F
AH30
0x01
AH30
0x02
AH30
0x03
AH30
0x04
AH30
0x0F
Address 1-15
. . .
The communication hub must be power
cycled after changing the address, since
the state of the DIP switch is read only at
startup.
Figure 16. Address