EasyManua.ls Logo

Assa Abloy Cabinet Lock Series - Power Cabling Guidelines; Install Strike Plate; Install Single Door Strike Plate

Assa Abloy Cabinet Lock Series
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Part Number 3085006.001, Rev 3
NOTE: It is recommended that 10-conductor, 24 AWG, cable be used.
11. ENSURE the following power cabling guidelines are followed:
Wire AWG
Supply Voltage
Allowed Cable Length (ft.)*
20 AWG
12
872
24
6679
22 AWG
12
548
24
4201
24 AWG
12
345
24
2641
* Round trip loss. V = 2 x I x R x xft xft = V / (2 x I x R)
12. POSITION the cable out of the way, as required.
13. PREPARE for the single door strike plate. (If installing on a double door, skip to Step 15)
a. PEEL OFF the protective layer of the Strike Plate Template and ALIGN it to both the latch centerline and the
cabinet edge.
b. DRILL the two pilot holes shown on the template.
c. REMOVE the template.
CAUTION
The Installer must ensure that the lock can be opened before closing the cabinet door.
14. INSTALL the single door strike plate.
a. PLACE the strike plate over the pilot holes, and INSERT and TIGHTEN the two screws in the slotted
holes.
b. CLOSE the door to verify installation, and ADJUST the strike plate if necessary.
c. INSERT and TIGHTEN the lock down screw on the strike plate.