Universal Door Closers
with A3 Heavy Duty
Non-Hold Open Parallel Arm
A3 Arm
Heavy Duty Non-Hold Open
IMPORTANT:
An improperly installed or incorrectly adjusted door closer may cause
or and will void product warranty.
To avoid personal injury,
property
damage personal injury;
DO NOT DISASSEMBLE THIS DOOR CLOSER BODY.
Door closers must be securely fastened to a properly reinforced door and frame
with fasteners provided.
An auxiliary door stop, BY OTHERS, is required for this Installation.
TO DETERMINE
HAND OF
YOUR DOOR:
LEFT
HAND
DOOR
RIGHT
HAND
DOOR
Size of Door&Door Closer
Type
of
Installation
Interior
Exterior
In-swinging
Exterior
Out -swinging
Recommended
Closer Size
**Max.
Opening
Force
lbs/f
2 4
2 6
3 0
3 6
4 0
4 6
' "
' "
' "
' "
' "
' "
2 6
3 0
3 6
4 0
' "
' "
' "
' "
8
14
16
22
24
26
1
2
3
4
5
6
Parallel
Arm
RHR
LHR
80-9380-8002-152 Rev. 07/09
DC8210 Series
Multi-Sized1thru 6
BEFORE
INSTALLING:
ADA compliant closer: DC8210.
The Americans with Disabilities Act (ADA) requires that doors having door closers
have an opening force not to exceed 5 lbf.
The door closer's power size adjustment feature may require adjustment to its
lowest setting to comply with ADA opening force guidelines.
As Easy As
A
C
B
F
Installation Instructions
1
**NOTE: These forces are for standard templating with bearing type hinges and do not account for pressure differentials and draft.