22
Delayed Egress
Installation Instructions
ED4000, ED5000 Series Exit Device
FM209 10/20
Copyright © 2006, 2010, 2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
21 Additional Options Non ElectroLynx Wiring
Orange
White
Green
NC
NO
C
Ta n
Gray
Pink
NC
NO
C
Figure 16
Latchbolt Monitor
Switch
(M91) Suf x
Upon depressing the pushpad for 1 second or longer, the device will sound an audible beeping tone
and allow the door to be opened within 15 (or 30) seconds. The tone will then change to a continuous
alarm until reset. Resetting of the alarm and re-arming of the device occurs automatically once the door
has been returned to the closed position for 30 seconds. The 30-second re-arming timer will re-start if
the pushpad is depressed or the door is re-opened before actual re-arming of the device occures. A DPS
(Door Position Switch) is required for the BOCA option.
NOTE: BOCA option is not suitable for installations in accordance with NFPA 101.
Electrically Controlled Trim (Mortise Device) “Safe/Secure”
The Delayed Egress Exit Device is available with Fail Safe (SAF) or Fail Secure
(SEC) outside trim operation. In a fire condition, the Fail Safe trim will release
for entry. When Access control is used, the Fail Secure trim allows entry by
means of a remote card reader, keyswitch, push button, etc.
Note: If a Door Position Switch is not used, the trim will open the door without
affecting the device in an armed condition (refer to wiring diagrams for wiring).
Outside Trim Monitor
Switch
(M93) Suf x
Figure 15
This option is used when outside trim is desired to be used with an external
Door Position Switch (by others). This switch will allow bypass (disarms device)
when the trim is used for ingress. The device will need to be reset upon entry by
means of the keyswitch on the device or a remote SPDT switch (refer to wiring
diagrams for wiring).
Note: If an external DPS is not used, Standard trim and Safe/Secure trim will
allow entry without affecting the device in an armed mode. The device will only
be affected when the push pad is depressed. Latchbolt monitor switch is a SPDT
switch that monitors security of latchbolt or vertical rods.
22 BOCA 15 Second Delay M89 and BOCA 30 Second Delay M90
20 Operating Instructions, continued
Re-arm After Closing for Inde nite Delay
With 40 second momentary egress setting (S2-4 ON & S2-5 ON), S2-8 ON, and an external DPS is wired to the
PCBA-after activation of momentary egress by cylinder key switch or external remote reset signal, if the Door/
DPS is open beyond 40 seconds, it will remain in momentary egress mode indefinitely and shall not enter alarm
mode. Then once the Door/DPS is closed, it will re-arm immediately. With (S2-4 ON & S2-5 ON) S2-8 OFF for
same scenario as above, the device will enter alarm mode after 40 seconds if the Door/DPS is still open. If Door/
DPS is closed before 40 seconds, it will re-arm immediately.
23 NFPA 101 Requirements: 30 Second Delay M88 Suffi x
Upon depressing the pushpad for 3 seconds or longer, the device will sound an audible beeping tone
and allow the door to be opened after 30 seconds. The tone will then change to a continuous alarm until
reset. Resetting of the alarm and re-arming of the device is accomplished by manual means only.