24
Delayed Egress
Installation Instructions
ED4000, ED5000 Series Exit Device
FM209 10/20
Copyright © 2006, 2010, 2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
24 Troubleshooting, continued
Yellow
Green
Red
Orange
Diagonistic LEDs Function
Yellow ON - LBM Bypass DIP switch position 7 is OFF-set ON
OFF- LBM Bypass DIP switch position is ON (normal operation)
Red (Push Rail Switch) ON- Rail Push Bar is depressed.
OFF- Rail Push Bar is released.
Orange (Door Status Switch) ON- Door Status Switch is open. Door is open/violated.
OFF- Door Status Switch is closed or DPS Bypass DIP switch position 6 is ON.
Green (Solenoid) ON- Rail Solenoid is energized. (+24 VDC from main board)
OFF- Rail Solenoid is de-energized.
Refer to the following table and notes for an explanation of each LED’s function.
NOTES:
1. When the rail is armed (in Delayed Egress
Mode) and the door is closed and latched,
the Red End Cover LED and the Green
Diagnostic LED should be ON only. All other
LEDs should be OFF.
2. With the rail armed, depressing the
rail push bar slightly will turn the Red
Diagnostic LED ON. The rail should go into
alarm immediately (no nuisance delay) or
after being pressed for 1, 2, or 3-second
nuisance delay setting. The rail will be in
the irreversible alarm mode - End Cover LED
is Amber with local audible beeping tone.
After a standard delay of 15 seconds (0r
30-second optional delay), the rail solenoid
de-energizes and passage is allowed. End
cover LED is green with alarm at a steady tone
which continues until reset by key switch.
3. When a Door Status switch is used and the
door is opened, the Orange Diagnostic LED
will turn ON, which indicates that the door
is not closed. When not using a door status
switch, DIP switch position 7 must be set to
ON, Orange Diagnostic LED shall be off.