55
ENEN
Operation
Permanent release
The door can be permanently unlocked.
The green LED lights up permanently during a permanent release.
Permanent unlocking
The permanent release is activated
· by pressing the key pushbutton in the unlock direction (Tab. 1 page47).
or
· by activating via terminals 19
or
· by permanent activation via terminals 9/10
or
· by a closed switching contact on terminals 11/12
or
· by activation via the external control panel 1332
or
· by activation via a DCB controller 970-TSBC.
Permanent release configuration
The permanent release via the key pushbutton must be activated via a jumper
(Tab. 1 page 47).
DIP switch S4-3 (Tab. 2 page48) can be used to set whether permanent release
takes place immediately via the key pushbutton or terminal 19 or with a delay of
five seconds.
Locking
A temporary release or permanent release can be interrupted at any time and the
door locked.
The red LED lights up permanently when locked.
Lock
The closed door is locked
· by pressing the key pushbutton in the locking
direction or
· by activating via terminals 17/20.
Restrictive condition
It is not possible to lock the door when an alarm is present.