Copyright © 2016, 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9316-2535-020 Rev 3 04/20
5
1600SS Parallel Arm Installation (Right Hand Shown)
2. Close latch and sweep valves. 3. Install soft plate and
mount closer.
Door
Opening
To 100°
101° to 130°
131° to 180°
A
9-1/4
(235)
7-3/4
(197)
5-3/4
(146)
B
7-5/8
(194)
6-1/8
(156)
4-1/8
(105)
C
8-5/8
(219)
7-1/8
(181)
5-1/8
(130)
Door/Wall/Hardware/Jamb
conditions permitting
S
L
Holes for 1688
Plate only
1-1/2
(38)
7
(178)
4
(102)
2-1/8
(54)
3-1/4
(83)
1/2
(13)
3/4
(19)
9-1/16
(230)
C
L
C
B
Top of
Door
Frame
(70)
3/8
(10)
1/2
(13)
7/16
(11)
2
(50)
A
L
S
5. Remove arm shoe and install
forearm to soft plate.
6. Place main arm on closer spindle and rotate.
R
o
t
a
t
e
IMPORTANT
1. Prepare door and frame.
4. Take arms apart at elbow.