Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9359-0001-020 (01-14) Rev 3
12
Troubleshooting
Jump activation input
Change the setting of the ON/OFF/Hold open
Turn SPTE to 0°
Unlock the lock
Remove object
Turn potentiometer SPTE until the door-stop hits the
Change the setting of the ON/OFF/Hold open
Remove object
• Turn up the potentiometer SPTE until it is possible
Fault Possible reasons why Remedies/Explanations
The door does not open
- The motor does not start
Control switch is set to OFF position
switch
Electrical power is missing
Check the electrical power switch
Activation unit does not function
Presence detection is activated
Check that there are no objects in the detection zone
Potentiometer SPTE not turned to 0°
- The motor starts
Mechanical lock is locked
Something jammed beneath the door
Electric strike plate is binding
Select toggle dip switch for lock release
Adjust strike
Arm system has come loose
stop-block. Put the door in required open position.
Tighten the arm system. Turn SPTE to 0°
The door does not close
Control switch is set to HOLD
switch
Presence input is activated
Remove objects in the detection zone
Something jammed beneath the door
The operator has
unknown spring
tension
Too many adjustments carried out
to loosen the door arm stop
• Remove the door stop and the arm system
• Unplug the electrical power and let spring close
• Unplug the motor plug
• Mount the drive arm from the arm system and
find the 0 tension by moving back and forth
• Loosen the arm
• Connect the motor plug
• Connect the electrical power
• Turn the SPTE pot to 210° and wait until the
spindle stops turning
• Mount the door stop against the closing stop
block
• Turn down SPTE to 0° - operator is now factory
set
• Turn to section 9 to adjust open stop position