Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9359-0001-020 (01-14) Rev 3
4
Technical Data
120VAC, 60Hz
max. 75 W
24 V DC, max. 400 mA
2 x T 6.3 AH 250 V
36-48" (914-1219 mm)
100-200 lb. (45-90 kg)
Push arm: 80° - 110°, with reveal 0 - 7"
variable between 3 - 6 seconds
variable between 3 - 6 seconds
Power supply:
Power consumption:
Auxiliary voltage:
Internal control fuse:
Door width:
Electromechanical locking
device
Selectable: 12V DC, max. 500 mA / 24 V DC,
max. 250 mA
Door weight:
Door opening angle:
(0 - 178 mm)
Pull arm: 80° - 110°, with reveal 0 - 1/8"
(0 - 3 mm)
Opening time (0° - 80°):
Closing time (90° - 10°):
Hold open time:
1.5-30 seconds (A.D.A. 5 seconds min.)
Ambient temperature:
-4 °F to +113 °F (-20 °C to +45 °C)
Relative humidity
(non-condensing)
Max. 85%
Notes: Input connections - torque to 4.8 in/lbs (.55nm)
Permanent wiring is to be employed as required by local codes.
Any unused conduit holes must be plugged with provided covers.
Activation devices: push plates, access control, mats, etc.
1/2" Threaded
Conduit Hole
(4 locations)
Right hand push application shown
Line Voltage (120VAC)
(Field Wiring)
Line voltage circuit & low voltage circuit
must be in separate conduits.
Plug Unused
Holes With
Provided Covers
Low Voltage
(Field Wiring)
Strain Relief
Suitable strain relief must be provided upon
installation if the conduit bracket is used; strain
relief is to be provided by the installer.
Activation Device
Locking Device +vdc
Locking Device -vdc
Class 2 Supply 24 VDC
Use Copper Conductors Only
Com 120vac
Ground
HOT 120vac