Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9359-0001-020 (01-14) Rev 3
6
Auxiliary Control Board
1
1
ON
2
+24 V DC
O/C
GND
–
+
1
ON
2
0.5 s
0 s
Not Used
Latch Speed
a)
Lock Release
b)
Fail Secure - OFF / Fail Safe - ON
12 V shown (OFF) / 24 V (ON)
Potentiometer for opening delay
Toggle/Executive function (15 minutes maximum hold open)
Ground
12V DC max. 500 mA / 24 V DC max.
250 mA, see DIP-switch No. 1 below
Not Used
a)
The “latch speed” complies with the ANSI/BHMA 156.19 requirements.
Position OFF: Smooth closing
Position ON: Faster, more powerful latch
b)
Pulls door closer to the jamb to free latchbolt. If the switch is set to ON, the “lock release”
is active during the opening delay time set by the potentiometer. For “pair of doors”
3 4 5
3 4 5
3 s
2 3 4 5 6 7 8 9 10 11 12 13
installations, the “lock release” works in sequence; master then slave.
N/A
shown in
Off position
NOTE: If auxiliary contacts are
required, specify optional relay logic
module (part # 5900RLM).