21
6000 Series Wiring Diagrams
24VDC Fail Secure Electric Strike or Electric Exit Device
Door is normally closed and latched.
Activating switch will unlock electric strike
or exit device and door will automatically
open. Door will close after hold open time
delay has expired.
Door will remain locked during power
failure.
Activation can be wall switch, card reader,
key switch, etc (Normally open momentary
dry contacts).
To turn on relay (Relay 2), Latch Retraction
(Output Connections, page 14) and/or
Open Delay (Set options, page 8) features
must be turned on using adjustment
procedures on pages indicated.