80-9360-1043-020 Rev 1 05/21
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
24
6000 Series Wiring Diagrams
MKA2 x 24V Strike
(change factory pre-wiring to illustration below - move NO to +24)
Input 9: Security Override
Continuous contact closure of this input triggers operator to
disable input 2 / Activation 2.
This is typically used for switching off an outside wall plate.
MKA2 shown is in Normally Closed position which has LED RED and Exterior
Wall Switch disabled.
To turn on relay (Relay 2), Latch Retraction (Output Connections, page 14)
and/or Open Delay (Set options, page 8) features must be turned on using
adjustment procedures on pages indicated.
Alternate 24V
Source (+V and -V
of Power Supply)
On/Off Key Switch
Securitron MKA2 shown