80-9360-1043-020 Rev 1 05/21
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
30
6000 Series Wiring Diagrams
Vestibule Function
Door is normally closed and
latched.
Activating outside door
switch will open outside door.
After vestibule time delay has
elapsed, a signal will be sent
to inside door which will then
open. Activating inside door
switch will open inside door.
After vestibule time delay has
elapsed, a signal will be sent
to outside door which will
then open. Both doors will
close when hold open time
delay has elapsed.
Activating optional inside
door switch located within
corridor will open inside door only. This
door will re-close after hold open delay has
elapsed.
Activating optional outside door switch
located within corridor will open outside
door only. This door will re-close after hold
open delay has elapsed.
Activation can be wall switch, card reader,
key switch, etc (Normally open momentary
dry contacts).
Changing input designation may be required.