Closer Adjustments
3
10
+
-
1/8"
Hex
Key
"B"
Backcheck
75°
1/8"
Hex
Key
"P"
Backcheck
Position
75°
90°
"S"
Sweep
5°
!
Never Close
backcheck valve
completely
!
Do not remove valves
from closer. Hydraulic
oil will escape.
1/8"
Hex
Key
w
o
e
l
r
S
F
r
a
s
t
e
Weaker
Stronger
Closing Speed Controls
• Valve "S" Controls Sweep Range from
full open to 5°.
• Valve "L" Controls Latch Range from 5°
to closed.
Opening Cycle
Valve "B" controls the strength of
cushioning in Backcheck Range.
NEVER close this valve completely – it
is not to provide a positive stop.
• Valve "P" adjusts the angle that back-
check is felt in the open cycle.
"L"
Latch
0°
5°
1/8"
Hex
Key
w
o
e
l
r
S
F
r
a
s
t
e
Electrical Connections
3
See Page 13 for Non-Detectored Units
See Page 14 for Detectored Units
See Page 15 for RF Units