• Power input to unit must be of the same voltage as that listed on the label.
• All wiring connections use standard wiring practice conforming to local wiring codes.
• Maximum wire size is 18AWG.
• Make input power connections to the terminal block or power supply using illustrations below.
RF REMOTE RECEIVER UNITS
ELECTRICAL CONNECTIONS
120V AC INPUT
Surface mount power input:
Remove appropriate
shaded area from
cover for surface
wired installations
only. Repaint cut
edges as necessary
to prevent corrosion.
7/8"
7/8"
2-5/8"
Clearance
For Strain Relief
Cover surface
facing ceiling.
24V AC/DC INPUT
!
Caution:
Determine proper
input power; 24V or 120V.
Make power connections as shown below.
Make power connections as shown below.
24V(+)
24V(-)
Terminal Block
Make Connections
Here
On/Off
Switch
12-24V
AC/DC
COM
NO
NC
Live
Neutral
Terminal Block
Make Connections
Here
On/Off
Switch
12-24V
AC/DC
COM
NO
NC
Ground
Power Supply