5200 Series Programming Instructions
13
80-9352-0022-020 Rev 2 06/23
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Wiring Diagrams
Single-Use Restroom Wiring Diagram
Configuration Overview
24V & RLY 1:
24VDC powered (wet) output,
supports locks and accessories up to 200mA.
These outputs must be used to configure a
restroom application with a fail-secure lock-
ing device.
y Sends power to connected devices after
restroom switch activation.
24V NO:
24VDC powered output, supports locks and
accessories up to 400mA.
y Sends power to connected devices after
occupancy input activation.
Available Input functions:
y Occupancy Input (NO, momentary/pulse):
‒ Disables inside and outside restroom
switches.
y Restroom Outside Switch:
‒ In unlocked state, activates operator.
‒ Disabled by occupancy input; resets to
unlocked state when door is opened.
y Restroom Inside Switch:
‒ Activates operator.
‒ Disabled by occupancy input, while
occupancy input switch is closed.
This operator is capable of supporting many single-use restroom configurations through its powered outputs and
user-configurable inputs.
Some examples of Single-Use Restroom configurations are available on pages 14, 15, and 16.
Below is a detailed description of each variable that can be used for these configurations.