EasyManua.ls Logo

Assa Abloy NORTON RIXSON 5200 Series - Single-Use Restroom Wiring Diagram (Cont.); Example 1: Mortise Lock

Assa Abloy NORTON RIXSON 5200 Series
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5200 Series Programming Instructions
14
80-9352-0022-020 Rev 2 06/23
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Single-Use Restroom Wiring Diagram (cont.)
Example 1: Mortise Lock
Outside
Restroom
Switch
PUSH
TO
OPERATE
PUSH
TO
OPERATE
Inside
Restroom
Switch
+
C
NO
Fail-safe Electric Strike
24VDC
Deadbolt Monitor
Hardware Components
y One (1) Privacy function mortise lock w/
deadbolt and privacy indicator
y One (1) Electric strike w/ deadbolt
monitor*
y One (1) 5200 Series Low Energy Operator
y Two (2) Activation switches
Description of Operation:
y Door normally closed and unlocked.
y Outside door switch activates operator.
y Projecting deadbolt disables inside and
outside door switch, changes occupancy
indicator status.
y Retracting deadbolt re-enables inside
door switch.
y Exiting room re-enables outside door
switch.
Input Configuration:
Outside
Restroom
Switch
PUSH
TO
OPERATE
PUSH
TO
OPERATE
Inside
Restroom
Switch
+
C
NO
Fail-secure Electric Strike
24VDC
Deadbolt Monitor
*Fail-secure Configuration
Fail-safe Configuration
*Output to configure fail-secure electric strike for
restroom function provides up to 200mA

Other manuals for Assa Abloy NORTON RIXSON 5200 Series