5200 Series Programming Instructions
16
80-9352-0022-020 Rev 2 06/23
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Single-Use Restroom Wiring Diagram (cont.)
Example 3: Touchless
Outside
Wall Plate
Inside
Wall Plate
+
Fail-safe Electric Strike
24VDC
Wave to
Lock
+
+
Outside
LED
Inside
LED
+
C
NO
WAVE TO
OPEN
+
C
NO
WAVE TO
OPEN
WAVE TO
LOCK
+
C
NO
Hardware Components
y One (1) Storeroom function lockset
y One (1) Fail-safe Electric strike
y One (1) 5200 Series Low Energy Operator
y Two (2) LED wall plates
(“Occupied When Lit)
y One (1) Touchless activation switch
(“Wave to Lock”)
y Two (2) Touchless activation switches
Description of Operation:
y Door normally closed and unlocked.
y Outside door switch activates operator.
y “Wave to Lock” switch locks electric strike,
disables outside door switch, illuminates LEDs.
y Inside door switch unlocks electric strike,
activates operator, re-enables outside door
switch and LEDs.
y Exiting room via inside lever unlocks electric
strike, re-enables outside door switch and
LEDs.
Input Configuration: