05/31/20
A8239B • 800-810-WIRE (9473) • www.sargentlock.com
13
Copyright © 2020, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
SE LP10 7000 Series Multi Point Lock
1. Position ET carefully onto the inside door surface
the inside of the door. Be careful not to pinch wire harness.
2. Mount inside trim lever using (2) # 1/4” -20 x 3” Philips oval head
machine screws. (Fig. 3B).
1. For exterior applications, use ET gasket (52-0263) to seal ET
escutcheon and outside door surface (Fig. 3A).
2. Feed wire through the through hole and attach the outside exit
trim to the door.
A. Outside Trim
3 Install Outside Trim and Inside Trim
B. Inside Trim
Fig. 3A
Outside
Exit trim
Fig. 3B
Inside
Exit Trim
Outside
of Door
Fig. 4A
Reader
Backplate
Fire
Shield
Fig. 4B
Gasket
(for exterior doors)
4 Install Reader Backplate and (Optional*) Fire Shield or Gasket
1. For fire-rated doors only, install reader backplate and fire shield to
door using two (2) #8-18 x 5/8” Phillips flat head self-drilling screws
(Fig. 4A).
2. For exterior doors, install reader backplate and gasket (Fig. 4B) using
two (2) #8-18 x 5/8” Phillips flat head self-drilling screws.
*For non-fire rated interior doors, no fire shield or gasket is required; simply
install backplate using two (2) #8-18 x 5/8” Phillips flat head self-drilling screws.