05/31/20
A8239B • 800-810-WIRE (9473) • www.sargentlock.com
5
Copyright © 2020, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
SE LP10 7000 Series Multi Point Lock
McKinney
Electric
Hinge
SE LP10
Wiegand Access
Control System
The reader requires 12VDC for power, while the lock
accepts either 12 or 24VDC.
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 12VDC
1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A
100 20 18 16 14 14 12 12 10
150 18 16 14 12 12 12 10 —
200 16 14 12 12 10 10 — —
250 16 14 12 10 10 10 — —
300 16 12 12 10 10 — — —
400 14 12 10 — — — — —
500 14 10 10 — — — — —
750 12 10 — — — — — —
1,000 10 — — — — — — —
1,500 10 — — — — — — —
Wire Gauge Chart 12VDC
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 24VDC
1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A
100 24 20 18 18 16 16 14 12
150 22 18 16 16 14 14 12 10
200 20 18 16 14 14 12 12 10
250 18 16 14 14 12 12 12 10
300 18 16 14 12 12 12 10 —
400 18 14 12 12 10 10 — —
500 16 14 12 10 10 — — —
750 14 12 10 10 — — — —
1,000 14 10 10 — — — — —
1,500 12 10 — — — — — —
Wire Gauge Chart 24VDC
Electrical Specifications
12/24VDC System
Specifications / Features (Continued)
4
12V 24V
Average Peak Average Peak
Reader
100mA 220mA n/a n/a
Actuator
15mA 500mA 15mA 500mA
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes and the authorities having jurisdiction.
This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70.
• UL 294 Access Control Ratings:
Destructive Attack Level 1
Line Security Level 1
Endurance Level 4
Standby Power Level 1
• UL Listed* - UL 294 Indoor Use
• CUL Listed - S319: Class 1
• ANSI/BHMA A156.25 Listed
Grade 1 Compliant
UL testing was conducted on product powered by
UL Listed model 9001GR/AC injector; manufactured
by Microsemi Corp.
*UL294, S319, & BHMA A156.25 currently not applicable