Instructions for Installation of
Keypad Rim & Mortise Exit Devices
KP8877 / KP8878
KP8977 / KP8978
All of the following procedures start with 99# (continued).
If after the last *” is depressed, the yellow LED does not go out, depress “*” once more.
To Deactivate “Beep” With the Depression of Each Key:
Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
30# 0# 0# (Yellow LED Continues to Blink Slowly)
* (Yellow LED Blinks Quickly)
* (No Beep on Depression and Yellow LED Blinks Slowly)
* (No Beep on Depression and Yellow LED Goes Out)
To Reactivate “Beep” With the Depression of Each Key:
Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
30# 0# 1# (Yellow LED Continues to Blink Slowly)
* (Yellow LED Blinks Quickly)
* (Beep on Depression and Yellow LED Blinks Slowly)
* (Beep on Depression and Yellow LED Goes Out)
To Clear the Entire Memory:
Master Code* (Yellow LED Begins to Blink Slowly)
46# 00000# 00000# (Yellow LED Continues to Blink Slowly)
* (Yellow LED Blinks Quickly)
* (No Beep on Depression and Yellow LED Goes Out)
PAUSE, Yellow LED Begins to Blink Again
* (Yellow LED Goes Out)
NOTE This Deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back
to 1234, Door Number to 0001 and Unlock time to 5 Sec. If the Master Code is not known, Factory
Assistance will be required to clear the memory. 1-800-810-WIRE.
To Program Door Numbers into Keypad:
Master Code* (Yellow LED Begins to Blink Slowly)
43# 0# Door Number# (must be four digits) (Yellow LED Blinks Slowly)
* (Yellow LED Begins to Blink Quickly)
* (Yellow LED Blink Slowly)
* (Yellow LED Goes Out)