18 Service / Maintenance
Regular inspections shall be made according to national regulations and product documentation
by an ASSA ABLOY Entrance Systems-trained and qualified technician. The number of service occa-
sions should be in accordance with national requirements and product documentation. This is
especially important when the installation concerns a fire-approved door or a door with an emer-
gency opening function.
As with all other technical products, an automatic door needs maintenance and service. It is essential
to know the importance of maintenance to have a reliable and safe product.
Service and adjustments will ensure a safe and proper operation of an automatic door unit.
The “Service Log Book” shall be used together with the “Site Acceptance Test and Risk Assessment”
document (PRA-0007) provided. Keep both documents available for maintenance and service re-
cords.
The table below shows the recommended interval in months, when to replace parts during pre-
ventive maintenance.
Abusive
Environment
Cycles/hour in operation
Part numberPart
>100<100<10
High
traffic
Medium
traffic
Low
traffic
60606060331003498Transmission unit
661224330000271BK/SIPUSH/PUSH-335 service kit
661224330000335BK/SIPULL/PULL-220 service kit
661224330000270BK/SIAdaptor kit
661224330000230
Door stop (transmission unit
until w.1947)
661224331019378
Stop arm kit (transmission unit
from w.1947)
661224331003887ST-V/H service kit
661224331019159Micro switch kit
24242424331003567Battery backup unit *
60606060331003532CU-ESD control unit
Disconnect mains when replacing battery.*
Risk of battery explosion if wrong type of battery is used. If Battery Monitoring DIP is ON, then
a reset of this is needed (after changed batteries), see section 5.4.6.
67Issue 2021-02-241005088-en-22.0
18 Service / Maintenance