12.4 Settings for double doors
Settings on the
Function
SecondaryPrimary
Common
XProgram selection
XOpening time
XClosing time
XHold open time
XClose / Continue to open when the door is obstructed
XPAG On/Off
XSOS On/Off
(X)*XLevel of Power assist
(X)*XExtended closing torque
XOPD/OPS Impulse or Mat Logic Impulse
XSelection of operating mode during operation on battery
power
Individual
XXLock/Unlock signal voltage
XXLocked without/with power
XXLock release Enable/Disable
XXOpen Delay Time
XXLock kick Enable/Disable
* For Double egress doors, these functions must be set separately for primary and secondary as
the arm systems as well as the air pressure may be different.
Note!
Locks on the primary and secondary doors must be connected to the control unit (CU) on the
corresponding operator.
Inner and outer impulses can be connected to either primary or secondary CU or both.
The OPD/OPS is to be connected to the primary CU except for Double egress, where each
OPD/OPS must be connected to corresponding CU.
Door leaf mounted sensors must always be connected to corresponding CU.
57Issue 2021-02-241009728-en-9.0