A confirmation by pushing the learn button is enough in following situations
- If any changing of the MAT-dip.
- When replacing any of the extension units.
- When changing of Locked with/without power.
- When changing of Lock 12/24 V.
Learn can be carried out with activation units and locks connected.
The back-check will be automatically adjusted to 10° and 1 second before open position. The
latch-check will be automatically adjusted to 10° and 1.5 seconds before closed position.
10°/1 s
10°
1.5 s
Back-check
Latch-check
13.2.1 Push the LEARN BUTTON (LRN)
The door has no safety during auto-learn cycle. Remain clear of swing path of
door, as door may open and close rapidly.
When the learn button is pressed the status LED starts to blink and will not stop until learn is con-
cluded.
Note! Do not touch the door during the auto-learn cycle.
The learn cycle starts with sensor detection, during which the door will stand still. When the door
starts moving the spring tension and door inertia are measured and the door open and close position
is saved. When the learn is concluded the back-check, latch-check, opening time and closing time
are calculated. The changed settings affect the behavior of the installation and must be verified.
LRN
PAG
MAT
1
ON
2 3
CLTQPOAS
HOT
KHOT
13.2.2 Double doors
For double doors, the primary door must be learned first and thereafter the door. When the sec-
ondary door is learned, the primary door will open up to fully open position during the learning
phase of the secondary door.
The doors can also be learned separately before connecting the sync cable. In case of rebated doors
and separate learning, the primary door must be held open before the secondary door learn is
carried out.
13.3 General adjustment
a Set the hold open time with the potentiometer on the control unit.
b Adjust the opening speed (OPSP). Turning clockwise increases the speed.
1009728-en-9.0Issue 2021-02-2464