13.4 Connection of activation units and accessories
See sensor manuals for mounting and adjustments. Protective device shall comply with EN 12978.
Door mounted
When sensors are used in order to avoid contact with the door leaf it is required that the presence detect sensor
and the presence impulse sensor fulfills Performance Level = d according to EN ISO 13849-1. These sensors shall
also be monitored (tested) by ASSA ABLOY SW200 door operator.
A B C J E F G H
SP59-M
1 2 3 4
3 10
7
1
4
5
6
2
3
7
8
4
5
CU-200
CU-200
EXU-SI
EXU-SA
EXU-SA
EXU-SI
EXU-SI
EXU-SI
EXU-SA
EXU-SI
EXU-SA
EXU-SI
9
1 2 3 4 5
3
10
11 12
SP51-M**
A B C D E F G H
1 1 1 2 4 5 5
3 54 5
1 1 1
SP33-M
1 1 1 2 4 5 5
3 54 5
1 1 1
1 2
1 3
PRESS
TO OPEN
3 6
3 4
4
3
7
7
3
10
3 8
6 1 2
6( 1 3)*
13 3 4
+
GND
IMP
A C H B F D I E
1 1 1 2 4 5 5
3 54 5
1 1 1
Configue sensor SP33-M:
DIP A7 to ON (for primary sensor)
DIP B4 to ON for presence impulse
DIP B4 to OFF for presence detection
** Note! When using the quick connector, open-
ing and closing side will be reversed.
Activation
sensor
PS-4C
Fire
alarm
BrownAInner impulse
1
YellowBOuter impulse
2
PinkCKey Impulse
3
VioletDPresence impulse
4
WhiteEPresence detection
5
BlueFOff
6
RedGKill impulse NO
7
GreenHKill impulse NC, fire alarm, smoke detector
8
BlackIFire alarm reset
9
GreyJStandard*
1009728-en-9.0Issue 2021-02-2466