14. REMOTE SYSTEM LOCKDOWN
Remote System Lockdown is an optional feature that restricts the user from interacting with the system when an external
alarm is triggered. A third party alarm is wired into the Traka Touch and when triggered, will put the system into
‘lockdown’.
This is a standalone Traka Touch feature i.e. does not require TrakaWEB. When in lockdown mode, the system will refuse
automated remote login/item release requests from TrakaWEB. No users will be able to gain access to items or system
functions until the lockdown has been lifted.
14.1 REQUIREMENTS
To use the remote system lockdown feature you will require the additional Traka CAN Relay Interface PCB. This
additional hardware can be added to your system by a Traka engineer after your initial installation. The feature
may then be enabled through Traka Touch. No further software configuration is required.
An alarm that can be wired into the Traka CAN Relay Interface PCB.
The alarm must be non-voltage contact.
NOTE: Refer to document TD0083, CAN Relay PCB Wiring Guide for details on pinouts and wiring
specifications.
14.2 USING THE SYSTEM
The system can be used as normal until the alarm is activated. On alarm activation, the user interface will display a
message informing that system access is currently blocked, preventing the user from logging in.
NOTE: The system will come out of the screensaver or ‘idle’ mode to go into lockdown.
‘System in lockdown mode’ is displayed in the default system language and also cycles in all other supported languages.
This will continue to stay onscreen as long as the system is in lockdown.