15. RRSS (RANDOM RETURN TO SINGLE SYSTEM)
15.1 SYSTEM REQUIREMENTS
This feature can operate on a standalone Traka Touch system or can be used in conjunction with TrakaWEB. The
minimum Traka Touch Application version required is V1.6.0. If used in conjunction with TrakaWEB, the minimum
TrakaWEB version required is V2.3.0.
15.2 RRSS OVERVIEW
RRSS (Random Return to Single System) allows any iFob belonging to a system to be returned to any position within
that system. It will also support more iFobs than receptor sockets (up to a maximum of 720 iFobs in total). To do this,
each iFob is assigned a Unique Index number which stays with the iFob for life.
The RRSS feature works with both Locking and Non Locking receptor strips, and with systems with and without doors.
You cannot take an item and return it to a different system (that’s Random Return to Multiple Systems).
NOTE: To use the RRSS feature you must first have it enabled in the configuration file.
USEFUL TIP: Use the ‘I Need To Search’ option when removing iFobs for ease of locating required items.
15.3 ITEM SETUP
This setup process can only be performed by an Admin user.
1. Access the system and click Admin.
2. Click Items.
3. Click Setup. The system will ask if you want to deallocate all iFobs that are NOT in the system.
a. If you select YES, any iFobs not currently in the system will be deallocated. Their Index number will
not be reused in case a user has been granted access to that. You will also be unable to have more
iFobs than number of positions in the system.
b. If you select NO, it will allocate any new iFobs it finds in the system. This allows you to have more
iFobs allocated to the system than the number of positions in the system.
Once you have made your selection the system will display a list of all allocated items.