V9.7 01/05/20 UD0011 Page 13 of 177
This Document is uncontrolled when printed unless over stamped “CONTROLLED DOCUMENT"
3. PRODUCT DETAILS
NOTE: Please ensure that the correct installation procedures have been utilised and the product is safely
secured.
3.1 ELECTRICAL RATING
Power supply: Input: 100-240V AC 50/60Hz 35W Max
Battery backup:
V-Series – DC12v 7Ah
M-Series - DC12v 7Ah
S-Series - DC12v 4.2Ah
L-Series - DC12v 7Ah
3.2 ENVIRONMENTAL RATING
Operating temp: Ambient, for indoor use only (-5°C to +40°C at 95% non-condensing relative humidity)
3.3 COMPLIANCE LEVEL
The following compliance details apply to the M-Series, S-Series and L-Series systems.
3.3.1 USA AND CANADA
CAN/ULC S319
ULC S319 Class = Class 1
The product’s or component’s compliance to ULC-S319 would be invalidated through the use of any add-on, expansion,
memory, or other module manufactured or supplied by the manufacturer or manufacturer’s representative.
UL294
The levels of access/class of protection are summarised below:
• Attack Level – Level IV
• Endurance Level – Level IV
• Line Security Level – Level I
• Standby Power Level – Level IV
3.3.2 EUROPE
Contact Traka for a copy of the CE declaration of conformity.