18.7.4 TRAKA TOUCH L BATTERY LOCATION
Traka provide a backup battery already connected with every Touch System inside the UK. If for any reason you need
to connect/disconnect the battery yourself please follow this section and then refer to the connection code below.
1. Insert the master key into the CAM lock on the side of the system.
2. Turn the key 90° clockwise to open the door.
3. The door will now open granting you access to the strips and cover panels.
4. Using a 4mm Allen Key or T-bar, remove the two M6 x 25mm socket screws holding the cover panels in place.
5. Remove the cover panels and put them to one side.
6. The 1U blank and strengthener at the bottom of the system will become loose and can be put to one side.
7. The bottom of the system has a large access panel that can be slotted upwards then lifted forward and removed.