12
Technical data
❺
Characteriscs
Operang temperature
Air -5 to 43°C
Water
In “heang mode” from 15 to 40°C
In “cooling mode” from 8 to 28°C
Operang pressure
Refrigerant from 0,5 to 42 bar (from 0.05 to 4.2 MPa)
Water from 0 to 2 bar (from 0 to 0.2 MPa)
Power supply
220 - 240V ~ / 1 phase / 50-60 Hz (05/07/09/13/15/20/24/30)
380 - 400 ~ / 3 phase / 50-60 Hz (20T/24T/30T)
Admissible variaon in voltage ± 6 % (during operaon)
Hydraulic connecons 2 PVC Unions Ø 50
Type of refrigerant uid R32
Protecon rang IPX4
Frequency bands GHz 2.400 - 2.497
Radiofrequency emission power dBm +19.5
Installaon locaon Outdoors
Technical specications
Eco Elyo-05 Eco Elyo-07 Eco Elyo-09 Eco Elyo-13 Eco Elyo-15 Eco Elyo-20
Operang power (max-min speed) kW 5.5 - 1.5 7 - 2 9.5 - 2.3 13 - 2.4 15 - 2.5 20-7.6
Consumed power (max-min speed) kW 0,9 - 0,1 1.1 - 0.15 1.4 - 0.2 2 - 0.1 2.5 - 0.15 3.6-0.6
COP (max-min speed) 6.1 - 14.4 6.5 - 13.4 6.7 - 13.5 6.5 - 16.4 6 - 16.3 5.5-12.3
Eco Elyo-20T Eco Elyo-24 Eco Elyo-24T Eco Elyo-30 Eco Elyo-30T
Operang power (max-min speed) kW 20-7.6 24-6.8 24-6.8 31-9.3 31-9.3
Consumed power (max-min speed) kW 3.6-0.6 4.4-0.5 4.4-0.5 5.6-0.7 5.6-0.7
COP (max-min speed) 5.5-12.3 5.4-13.7 5.4-13.7 5.5-13.3 5.5-13.3
Performances: air at 26°C / water at 26°C / humidity at 80 %
Performances: air at 26°C / water at 26°C / humidity at 80 %
8