Chapter 7 ACTION SETTINGS
379
<Table of scroll setting items>
On or Off is set for window scrolling here.
0
OFF
Window scrolling is set to Off.
(1)
OFF/ON (0/1)
1
ON
Window scrolling is set to On.
The direction of scrolling is set here.
0
Left
The window is scrolled toward the left.
1
Right
The window is scrolled toward the right.
2
Up
The window is scrolled upward.
3
Down
The window is scrolled downward.
4
Left Up
The window is scrolled toward the top left.
5
Left Down
The window is scrolled toward the bottom left.
6
Right Up
The window is scrolled toward the top right.
7
Right Down
The window is scrolled toward the bottom right.
8
Left<->Right
The window is scrolled toward the left and right.
9
Up<->Down
The window is scrolled toward the top and
bottom.
(2)
Direction (0-A)
A
Random
The window is scrolled at random.
The interval (execution interval) mode for window scrolling is set here.
0
User
The window is scrolled as per the Interval 1-4
setting.
1
60i->60i
The interval (execution interval) is set to 1 V.
2 24p->
60i 2-3PullDown
The interval (execution interval) is set to 2 V and
3 V, and repeated.
3
25p->50i
The interval (execution interval) is set to 2 V.
(3)
Mode (0-4)
4
30p->60i
The interval (execution interval) is set to 2 V.
(4)
Interval (Interval 1)
The interval (execution interval) is set here. Setting range: 1 V to 255 V
This setting takes effect only when User has been selected as the Mode
setting.
The amount of movement per interval (execution interval) is set here.
H
Setting range: 1 dot to 255 dots
This setting takes effect only when Left or Right has been selected as the
Direction setting.
(5)
Step (Step 1)
V
Setting range: 1H to 255H
This setting takes effect only when Up or Down has been selected as the
Direction setting.
The following items are selected only when User has been selected as the Mode setting.
(6)
Interval 2 to 4
The interval (execution interval) is set here. Setting range: 0 V to 255 V
When a setting other than “0” has been selected, the conditions which have
been set are repeated in sequence starting with Interval 1.
Example: Interval 1 → Interval 2 → Interval 3 → Interval 1 →
The amount of movement per interval (execution interval) is set here.
The amount of movement corresponding to the Interval 2-4 setting is set.
H
Setting range: 0 dot to 255 dots
This setting takes effect only when Left or Right has been selected as the
Direction setting.
(7)
Step 2 to 4
V
Setting range: 0H to 255H
This setting takes effect only when Up or Down has been selected as the
Direction setting.